Hiroshi Ito, Reinhold Schwalm
JES
We have used scanning tunneling microscopy to locate and characterize electron trapping defects on in-situ oxidized Si(100) surfaces. When the tunneling tip is held stationary over a trap, the tunnel current switches between two well defined values. By changing the voltage on the tip we can establish the location of the trap in the tunneling direction and the trapping energies. © 1987.
Hiroshi Ito, Reinhold Schwalm
JES
Michael Ray, Yves C. Martin
Proceedings of SPIE - The International Society for Optical Engineering
Gregory Czap, Kyungju Noh, et al.
APS Global Physics Summit 2025
Frank R. Libsch, Takatoshi Tsujimura
Active Matrix Liquid Crystal Displays Technology and Applications 1997