H.H. Zappe
IEEE T-ED
To study the nondestructive readout properties of thick magnetic film devices, sense voltages are computed for triangular interrogate word pulses. Eddy currents are assumed to be the exclusive damping mechanism. For a given pulse rise time one can obtain a maximum signal peak value with a given optimum film thickness, and the read signal of an optimized film can be approximated by simple analytical functions. In an attempt to describe the nondestructive readout stability, a relation is developed between pulse widths, angle of rotation of the magnetization, and reversibility threshold. Copyright 1967 by The Institute of Electrical and Electronics Engineers, Inc.