C. Joachim, J.K. Gimzewski
Physical Review B - CMMP
The tip-surface region of a scanning tunneling microscope (STM) emits light when the energy of the tunneling electrons is sufficient to excite luminescent processes. These processes provide access to dynamic aspects of the local electronic structure that are not directly amenable to conventional STM experiments. From monolayer films of carbon-60 fullerenes on gold(110) surfaces, intense emission is observed when the STM tip is placed above an individual molecule. The diameter of this emission spot associated with carbon-60 is approximately 4 angstroms. These results demonstrate the highest spatial resolution of light emission to date with a scanning probe technique.
C. Joachim, J.K. Gimzewski
Physical Review B - CMMP
B. Reihl, J.K. Gimzewski
Surface Science
S. Modesti, J.K. Gimzewski, et al.
Surface Science
T. David, J.K. Gimzewski, et al.
Physical Review B