Tsuyoshi Idé, Keerthiram Murugesan, et al.
KAIS
Nocturnal hypoglycemia is a serious complication of insulin-treated diabetes, which commonly goes undetected. Continuous glucose monitoring (CGM) devices have enabled prediction of impending nocturnal hypoglycemia, however, prior efforts have been limited to a short prediction horizon (~ 30 minutes). To this end, a nocturnal hypoglycemia prediction model with a 6-hour horizon (midnight-6 am) was developed using a random forest machine- learning model based on data from 10,000 users with more than 1 million nights of CGM data. The model demonstrated an overall nighttime hypoglycemia prediction performance of ROC AUC = 0.84, with AUC = 0.90 for early night (midnight-3 am) and AUC = 0.75 for late night (prediction at midnight, looking at 3-6 am window). While instabilities and the absence of late-night blood glucose patterns introduce predictability challenges, this 6-hour horizon model demonstrates good performance in predicting nocturnal hypoglycemia. Additional study and specific patient-specific features will provide refinements that further ensure safe overnight management of glycemia.
Tsuyoshi Idé, Keerthiram Murugesan, et al.
KAIS
Tsuyoshi Idé, Hisashi Kashima
KDD 2004
Masashi Sugiyama, Tsuyoshi Idé, et al.
Machine Learning
Tsuyoshi Idé, Aurelie C. Lozano, et al.
SDM 2009