I. Khubeis, J.F. Ziegler
Nuclear Inst. and Methods in Physics Research, B
A method for the measurement of the concentration of hydrogen versus depth in solids using the 1H+15N resonant nuclear reaction is discussed. This method has a typical depth resolution of 50-100 Å, can be used to a depth of several microns, and can measure hydrogen in concentrations of one part per thousand or greater.
I. Khubeis, J.F. Ziegler
Nuclear Inst. and Methods in Physics Research, B
J.F. Ziegler, G.W. Cole, et al.
Journal of Applied Physics
Pei-I. Wang, S.P. Murarka, et al.
JES
R. Hasegawa, R.J. Gambino, et al.
Journal of Applied Physics